EN 469消防人員的防護服裝 消防防護服裝的要求和
EN 469:2005
Protective clothing for firefighters- Performance requirements for protective clothing for firefighting
clause |
Test item |
standard |
requirement |
|
6.1 |
Flame spread |
EN ISO 15025 :2002 Procedure A |
EN 533 Index 3 |
|
6.2* |
Heat transfer -Flame |
EN 367 |
Level 1 or 2 |
|
6.3* |
Heat Transfer -Radiation |
EN ISO 6942 |
Level 1 or 2 |
|
6.4* |
Residual tensile strength of material when exposed to radiant heat |
Pretreatment: EN ISO 6942 Method: ISO 13934-1 |
>= 450N |
|
6.5 |
Heat resistance |
ISO 17493 |
No ignite, melt , shrinkage <5% |
|
6.6 |
Tensile strength |
ISO 13934-1 |
>= 450N |
|
6.7 |
Tearing strength |
ISO 13937-2 |
>=25N |
|
6.8 |
Surface wetting |
EN 24920 |
>=4 Grade |
|
6.9. |
Dimensional change |
ISO 5077 |
< +-3% |
|
6.10. |
Resistance to penetration by liquid chemical |
EN ISO 6530 |
Repellency rate: < =80% |
|
6.11 |
Resistance to water penetration |
EN 20811 |
Level 1: < 20kPa, without moisture barrier Level 2: >=20kPa, with a moisture barrier |
|
6.12* |
Water Vapour Resistance |
EN 31092 |
Level 1: > 30m2/Pa/W Level 2: <=30m2/Pa/W |
|
6.13 |
Ergonomic performance |
Annex D |
/ |
|
6.14* |
Visibility |
EN 471 |
Annex B |
|
6.15 |
Optional test – whole garment testing |
Annex E |
/ |
|
One wash |
|
Note:
1. Clause 6.1 – 6.4, 6.8-6.12, one wash or dry cleaning is needed before test.
2. All the clause marked * need to be subcontracted out.